Tested Applications
| Positive FC detected in | human PBMCs |
Recommended dilution
| Application | Dilution |
|---|---|
| Flow Cytometry (FC) | FC : 0.2 ug per 10^6 cells in 100 μl suspension |
| This reagent has been tested for flow cytometric analysis. It is recommended that this reagent should be titrated in each testing system to obtain optimal results. | |
| Sample-dependent, Check data in validation data gallery. | |
Product Information
65134-1-Ig targets CD4 in FC applications and shows reactivity with Human samples.
| Tested Reactivity | Human |
| Host / Isotype | Mouse / IgG2b, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Immunogen |
Human peripheral T cells Predict reactive species |
| Full Name | CD4 molecule |
| Calculated Molecular Weight | 51 kDa |
| GenBank Accession Number | BC025782 |
| Gene Symbol | CD4 |
| Gene ID (NCBI) | 920 |
| ENSEMBL Gene ID | ENSG00000010610 |
| RRID | AB_2881474 |
| Conjugate | Unconjugated |
| Form | Liquid |
| Purification Method | Affinity purification |
| UNIPROT ID | P01730 |
| Storage Buffer | PBS with 0.09% sodium azide, pH 7.3. |
| Storage Conditions | Store at 2-8°C. Stable for one year after shipment. |
Background Information
CD4 is a 55-kDa transmembrane glycoprotein expressed on T helper cells, majority of thymocytes, monocytes, macrophages, and dendritic cells (PMID: 9304802; 12213222). CD4 is an accessory protein for MHC class-II antigen/T-cell receptor interaction. It plays an important role in T helper cell development and activation (PMID: 9539765; 3112582). CD4 serves as a receptor for the human immunodeficiency virus (HIV) (PMID: 9304802).
Protocols
| Product Specific Protocols | |
|---|---|
| FC protocol for CD4 antibody 65134-1-Ig | Download protocol |
| Standard Protocols | |
|---|---|
| Click here to view our Standard Protocols |
Reviews
What customers say
The single review for this product is a 5-star rating from a Flow Cytometry application. The user reported using 5 µL per test with ultracomp beads and cytotrol cells, and noted that the product worked well for conjugating their own synthesized dyes in-house. Overall, the feedback is positive, highlighting the antibody's utility in custom dye conjugation workflows and reliable performance in flow cytometry.
The reviews below have been submitted by verified Proteintech customers who received an incentive for providing their feedback.
Sunil (Verified Customer) (08-29-2023) | Use to conjugate our own synthesised dyes in our own lab and tested with ultracomp beads and cytotrol cells.
|