Human ESR2 ELISA Kit

Sensitivity

0.54 ng/mL

Range

3.13-200 ng/mL

Reactivity

Human

Cat no : KE00503

Synonyms

ESR2,ER BETA,Erb,ER-beta,ERβ



Product Information

KE00503 is a solid phase sandwich Enzyme Linked-Immuno-Sorbent Assay (Sandwich ELISA). The human ESR2 ELISA kit is to be used to detect and quantify protein levels of endogenous human ESR2. The assay recognizes human ESR2. An antibody specific for human ESR2 has been pre-coated onto the microwells. The human ESR2 protein in samples is captured by the coated antibody after incubation. Following extensive washing, another horseradish peroxidase (HRP)-conjugated antibody specific for human ESR2 is added to detect the captured human ESR2 protein. For signal development, followed by Tetramethyl-benzidine (TMB) reagent. Solution containing sulfuric acid is used to stop color development and the color intensity which is proportional to the quantity of bound protein is measurable at 450 nm with the correction wavelength set at 630 nm.

Product name Human ESR2 ELISA Kit
Tests 1 X 96 well plate
Sample type Cell lysate
Assay type Sandwich
Sensitivity 0.54 ng/mL
Range 3.13-200 ng/mL
Reactivity Human
Tested applications Sandwich ELISA
Gene ID (NCBI) 2100

Recovery

Sample TypeAverageRange
Cell lysate101%93%-108%

IntraAssay

Samplenmean ( ng/mL)SDCV%
1892.044.875.30
2820.150.683.35
3811.190.504.43

InterAssay

Samplenmean ( ng/mL)SDCV%
11688.975.466.14
21620.150.763.75
31611.100.433.89

Background Information

Estrogen receptor-beta (ESR2) is a member of the superfamily of nuclear receptors, which can transduce extracellular signals into transcriptional responses. It binds estrogens with an affinity similar to that of ESR1, and activates expression of reporter genes containing estrogen response elements (ERE) in an estrogen-dependent manner. DNA-binding by ESR1 and ESR2 is rapidly lost at 37 degrees Celsius in the absence of ligand while in the presence of 17 beta-estradiol and 4-hydroxy-tamoxifen loss in DNA-binding at elevated temperature is more gradual.

Properties

Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions.
Synonyms ESR2,ER BETA,Erb,ER-beta,ERβ

FAQ

1、I have limited sample diluent. How should I handle samples requiring high dilution factors?

Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows:
Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample.
Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample.
Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample.
If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.

||