Use Able AI chat for product recommendations

Human MARS ELISA Kit

Sensitivity

0.07 ng/mL

Range

0.156-10 ng/mL

Reactivity

Human

Cat no : KE00432

Synonyms

MARS,MARS1,EC:6.1.1.10,Methionine--tRNA ligase, cy



Product Information

KE00432 is a solid phase sandwich Enzyme Linked-Immuno-Sorbent Assay (Sandwich ELISA). The human MARS ELISA kit is to be used to detect and quantify protein levels of endogenous human MARS. The assay recognizes human MARS. An antibody specific for human MARS has been pre-coated onto the microwells. The human MARS protein in samples is captured by the coated antibody after incubation. Following extensive washing, another horseradish peroxidase (HRP)-conjugated antibody specific for human MARS is added to detect the captured human MARS protein. For signal development, followed by Tetramethyl-benzidine (TMB) reagent. Solution containing sulfuric acid is used to stop color development and the color intensity which is proportional to the quantity of bound protein is measurable at 450 nm with the correction wavelength set at 630 nm.

Product name Human MARS ELISA Kit
Tests 1 X 96 well plate
Sample type Cell lysate
Assay type Sandwich
Sensitivity 0.07 ng/mL
Range 0.156-10 ng/mL
Reactivity Human
Tested applications Sandwich ELISA
Gene ID (NCBI) 4141

Recovery

Sample TypeAverageRange
Cell lysate107%104%-110%

IntraAssay

Samplenmean ( ng/mL)SDCV%
1205.440.5510.02
2201.190.097.62
3200.740.023.36

InterAssay

Samplenmean ( ng/mL)SDCV%
1245.560.437.65
2241.180.086.44
3240.700.057.41

Background Information

Methionyl-tRNA synthetase (MARS) belongs to the family of 20 enzymes essential for protein biosynthesis. Methionyl-tRNA synthetase (MARS) is essential for translation. MARS mutants reduce global translation, which usually increases lifespan in various genetic models. Although MARS has evolutionary conserved and significant in translation control, the physiological function of MARS at the organism level is not well studied.

Properties

Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions.
Synonyms MARS,MARS1,EC:6.1.1.10,Methionine--tRNA ligase, cy

FAQ

1、I have limited sample diluent. How should I handle samples requiring high dilution factors?

Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows:
Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample.
Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample.
Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample.
If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.

||