Use Able AI chat for product recommendations

Human OGG1 ELISA Kit

Sensitivity

0.04 ng/mL

Range

0.78-50 ng/mL

Reactivity

Human

Cat no : KE00477

Synonyms

OGG1,8 oxoguanine DNA glycosylase,8-oxoguanine DNA



Product Information

KE00477 is a solid phase sandwich Enzyme Linked-Immuno-Sorbent Assay (Sandwich ELISA). The human OGG1 ELISA kit is to be used to detect and quantify protein levels of endogenous human OGG1. The assay recognizes human OGG1. An antibody specific for human OGG1 has been pre-coated onto the microwells. The human OGG1 protein in samples is captured by the coated antibody after incubation. Following extensive washing, another horseradish peroxidase (HRP)-conjugated antibody specific for human OGG1 is added to detect the captured human OGG1 protein. For signal development, followed by Tetramethyl-benzidine (TMB) reagent. Solution containing sulfuric acid is used to stop color development and the color intensity which is proportional to the quantity of bound protein is measurable at 450 nm with the correction wavelength set at 630 nm.

Product name Human OGG1 ELISA Kit
Tests 1 X 96 well plate
Sample type Cell lysate
Assay type Sandwich
Sensitivity 0.04 ng/mL
Range 0.78-50 ng/mL
Reactivity Human
Tested applications Sandwich ELISA
Gene ID (NCBI) 4968

Recovery

Sample TypeAverageRange
Cell lysate114%109%-119%

IntraAssay

Samplenmean ( ng/mL)SDCV%
1821.890.562.56
285.980.264.27
382.930.103.27

InterAssay

Samplenmean ( ng/mL)SDCV%
11622.741.205.29
2165.920.284.81
3163.060.175.49

Background Information

8-Oxoguanine DNA glycosylase 1 (OGG1) is a tailored repair enzyme that recognizes 8-oxoGua in DNA duplex and initiates the base excision repair (BER) pathway to remove the lesion and ensure the fidelity of the genome. OGG1 is a multifaceted therapeutic target. The accumulation of genomic 8-oxoGua and the dysfunction of OGG1 is readily linked to mutagenesis, and subsequently aging-related diseases and tumorigenesis.

Properties

Storage Instructions All the reagents are stored at 2-8℃ for 6 months or -20℃ for 12 months. Refer to the protocol for further storage instructions.
Synonyms OGG1,8 oxoguanine DNA glycosylase,8-oxoguanine DNA

FAQ

1、I have limited sample diluent. How should I handle samples requiring high dilution factors?

Answer: We recommend performing a serial dilution. For example, if human serum requires a 1,000,000-fold dilution, you can use a three-step 100× dilution method as follows:
Step 1: Take 2 uL of human serum and add it to 198 uL of sample diluent, mix thoroughly to obtain a 100-fold diluted sample.
Step 2: Take 2 uL of the 100-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 10,000-fold diluted sample.
Step 3: Take 2 uL of the 10,000-fold diluted sample and add it to 198 uL of sample diluent, mix thoroughly to obtain a 1,000,000-fold diluted sample.
If further dilution is required, additional serial steps can be used. We do not recommend using any other solutions or water for dilution, except for the sample diluent we suggest. If your sample diluent is still insufficient, please contact our customer service for more sample diluent.

||
New chat